Conettix D6600 Manual do Utilizador Página 85

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 168
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 84
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 85
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
290.
Fail To Call
RAM
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM
h1rrlssssssaaaasTsF02t
<header>[#aaaa|NRA]
Control panel
attempted to call RAM
and was unsuccessful.
291.
Fire Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NriaFAppp]
Alarm signal from the
POINT (programmed
with a Fire Point code)
and the AREA in the
second line of the
report.
1,
10.
292.
Fire Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaa FIRE FR z
h1rrlssssssaaaasFssszt
<header>[#aaaa|NFAz]
2,
3,
9.
293.
Fire Alarm
(Area Not
Reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ ACC aaaa POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NFAppp]
Alarm signal from the
POINT (programmed
with a Fire Point code)
and the AREA in the
second line of the
report.
294.
Fire Alarm
(point < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NriaFMppp]
295.
Fire Alarm
(point < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa SMOKE DETECTED
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NriaFAppp]
296.
Fire Alarm
(point < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa HIGH TEMPERATURE DETECTED
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NriaKAppp]
297.
Fire Alarm
(point < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa WATER FLOW DETECTED
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NriaSAppp]
298.
Fire Alarm
(point < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasFppppt
<header>[#aaaa|NriaaFApppp]
299.
Fire Alarm
Cross point
(point > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasFppppt
<header>[#aaaa|NriaaFMpppp]
300.
Fire Alarm
Crossed Point
(Area Not
Reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ ACC aaaa CROSS POINT
+++ ACC aaaa POINT=ppp
h1rrlssssssaaaasFspppt
<header>[#aaaa|NFMppp]
Alarm signal from the
POINT (programmed
with a Fire Point code)
and the AREA in the
second line of the
report.
301.
Fire Alarm
Smoke
(point > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE ALARM
+++ACC aaaa SMOKE DETECTED
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasFppppt
<header>[#aaaa|NriaaFApppp]
Vista de página 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 167 168

Comentários a estes Manuais

Sem comentários