Modem4/ModemIIIa² Messages
SDI Device Missing Battery Reset
(4-digit Device)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISS BATT REST
+++ACC aaaa BATT=bb SDI=dddd
h1rrlssssssaaaasRsssDt
<header>[#aaaa|NpiddddEVbb]
Message
SDI Device Low Battery Restoral
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa DEV BAT RESTORE
+++ACC aaaa SDI=ddd
h1rrlssssssaaaasRsssDt
SDI Device Missing
(4-digit Device)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa DEVICE MISSING
+++ACC aaaa SDI=dddd
h1rrlssssssaaaasTsssDt
<header>[#aaaa|NpiddddEM]
Message
SDI Device Missing Restore
(4-digit Device)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa DEV MISSING RST
+++ACC aaaa SDI=dddd
h1rrlssssssaaaasRsssDt
<header>[#aaaa|NpiddddEN]
Message
SDI Device Trouble
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa DEVICE TROUBLE
+++ACC aaaa SDI=ddd
h1rrlssssssaaaasTsssDt
SDI Device Trouble Restore
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa DEV TROUBLE RST
+++ACC aaaa SDI=ddd
h1rrlssssssaaaasRsssDt
Sensor Reset
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=a ID=iii RELAY#=rrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nria/idiiiXIrrr]
(4-digit Relay)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=aa ID=iii RELAY#=rrrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nriaa/idiiiXIrrrr]
Sensor Reset
(4-digit User / Device)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=a ID=iiii RELAY#=rrrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nria/idiiiiXIrrrr]
Sensor Reset
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=aa ID=iii RELAY#=rrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nriaa/idiiiXIrrr]
Sensor Reset
(4-digit User)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=aa ID=iiii RELAY#=rrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nriaa/idiiiiXIrrr]
Sensor Restore
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaRQspppt
<header>[#aaaa|NriaXNppp]
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaRQppppt
<header>[#aaaa|NriaaXNpppp]
Sensor Trouble
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasQspppt
<header>[#aaaa|NriaXKppp]
Sensor Trouble
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasQppppt
<header>[#aaaa|NriaaXKpppp]
Service Bypass
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SERVICE BYPASS
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasNppppt
<header>[#aaaa|NriaaUBpppp]
Message
Service Bypass Restore
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SERVICE RESTORE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaRBppppt
<header>[#aaaa|NriaaUUpppp]
Message
Service End
(2212)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa SERVICE END
h1rrlssssssaaaasRsssFt