Conettix D6600/D6100IPv6/D6100i
|
Computer Interface Manual | 3.0 Computer Communication
Protocols
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Table 70: RB2000 (Message Type R) Printer Output
Characters Description
MM/DDsHH:MM Date and time.
RB2 RB2000 format.
Lxx Line number.
ACCT
xxxxxxxxxxxx
Subscriber number, up to 12 characters(hex).
RB2000_EVENT_R
AW_DATA
The raw data of RB2000 event.
RB2000_EVENT_R
AW_DATA1
The raw data of RB2000 event 1.
RB2000_EVENT_R
AW_DATA 2
The raw data of RB2000 event 2.
RB2000_EVENT_R
AW_DATA n
The raw data of RB2000 event n.
3.2.17 Robofon (Message Type j)
Robofon
Example
SIA Mode Description
<LF><CRC><j><sequence#><receiver#><line#>[#aaaaaa|EE]<CR>
Table 71: Robofon (Message Type j) Byte Description
Title Description
LF Standard line feed character.
CRC Cyclical redundancy check number.
Message Type j
sequence# The message sequence number. The valid sequence number range is 0001
to 9999.
receiver# The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
account # The communicator's account number has up to six digits.
EE Event code.