Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3.2.28 Varitech FSK 4-1 (Message Type <TAB>)
Varitech FSK
4-1 Example
SIA Mode Description
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR>
Table 88: Varitech FSK 4-1 (Message Type <TAB>) Byte Description
Title Description
LF Standard line feed character.
CRC Cyclical redundancy check number.
Message Type <TAB>
sequence# The message sequence number. The valid sequence number range is 0001
to 9999.
receiver# The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99 The receiver uses Line 0 (zero) for internal messages.
account# The communicator's account number has four digits.
data The event type and 1-digit zone number.
3.2.29 Varitech FSK 4-2 (Message Type <TAB>)
Varitech FSK
4-2 Example
SIA Mode Description
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR>
Table 89: Varitech FSK 4-2 (Message Type <TAB>) Byte Description
Title Description
LF Standard line feed character.
CRC Cyclical redundancy check number.
Message <TAB>
sequence# The message sequence number. The valid sequence number range is 0001
to 9999.
receiver# The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
account # The communicator's account number has four digits.
data The event type and two-digit zone number.