3.2 SIA Mode Messages
Use the SIA mode for central station monitoring.
3.2.1 Acron Super Fast (Message Type 9)
Acron Super
Fast Example
SIA Mode Description
<LF><CRC><9><sequence#><receiver#><line#>[#aaaa|CCCCCCCC]<CR>
Table 41: Acron Super Fast (Message Type 9) Byte Description
Title Description
L Standard line feed character.
CRC Cyclical redundancy check number.
Message Type 9
sequence# The message sequence number. The valid sequence number range is
0001 to 9999.
receiver# The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
account# The communicator's account number has four digits.
Figure 7: Message sent to printer
mm/ddshh:mmsLxxsACNsACCTsaaaa
+++sACCTsaaaasCCCCsCCCC
For lines that are grouped, Gxx appears instead of Lxx.
Table 42: Acron Super Fast (Message Type 9) Printer Output
Characters Description
ACN Acron Super Fast format.
Lxx Line number.
Gxx Grouped line numbers.